SM SYSTEMS · HVAC INTELLIGENCE

How AI controls HVAC

Data → system model → forecast → optimisation → command → building response.

HVAC Intelligence analyses the actual state of the building, forecasts demand and calculates the optimal equipment operating mode.

Decisions are sent to the BMS or controllers, and the system’s actual response is fed back into the model.

The system does more than observe what is happening. It calculates what needs to happen next.

Based in Ukraine. We deliver physical HVAC projects across Ukraine, while remote HVAC Intelligence services are available for buildings across Europe.

01. The system sees the actual state of the HVAC system

A single sensor explains nothing on its own. HVAC Intelligence works with the entire system simultaneously.

HVAC / PLC

Equipment

  • Temperatures and pressures
  • Heat transfer fluid and air flow rates
  • Pump and fan drive frequencies
  • Valve positions
  • Operating setpoints and statuses

METERING

Energy

  • Energy consumption
  • Heating and cooling output
  • COP / EER
  • Operating history

BUILDING / WEATHER

Building and environment

  • Outdoor air temperature
  • Weather forecast
  • CO₂
  • Building occupancy
Unified system state
  • Timestamps
  • Units of measurement
  • Data reliability

The available data points depend on the equipment and metering in place. COP / EER are calculated when sufficient power measurements are available, not from temperature alone.

02. Data becomes a digital system model

Temperature or power alone is not enough. The model describes what is installed, how circuits are connected and how the building responds to changes in operation.

01

Heating and cooling sources

  • Chillers
  • Heat pumps
02

Transfer and storage

  • Pumps
  • Hydraulic circuits
  • Buffer vessels
  • Valves
  • Heat exchangers
03

Distribution within the building

  • AHU
  • Heating
  • Cooling
  • Ventilation
04

Controlled system

  • Building
  • Zones
  • Thermal inertia

Shared constraints: capacity, minimum flow rates, permissible temperatures and time between starts.

AI does not work with a collection of sensors. It works with a model of the engineering system.

03. The system predicts what happens next

Predictive HVAC control accounts for future demand: operation can be adjusted before the temperature moves outside the agreed limits.

Thermal Load

Heating demand

How much heat the building needs.

Cooling Load

Cooling demand

How much cooling the zones will need.

Indoor Temperature

Indoor temperature

How indoor conditions will change over time.

Energy Demand

Electrical load

How much power the equipment will require.

Weather Impact

Weather impact

Outdoor temperature and solar gains.

Building Inertia

Thermal inertia

How long stored heat or cooling will last.

Forecasting changes when decisions are made
Cooling demandMeasurementsForecast
Illustrative building cooling demand forecast: a drop in load in 40 minutes.
MeasurementsNow+40 min+80 min

An illustration of the principle, not actual building telemetry.

BMS / PLCCollects data and executes local algorithms, schedules and safety functions.

HVAC IntelligenceCompares the predicted response of the entire system to different commands and recalculates the operating mode.

Predictive control complements the BMS rather than replacing its functions. The capabilities of a particular BMS depend on the software installed.

04. AI compares possible operating modes and selects the optimal one

Consider two identical chillers with separate pumps. The decision depends not on a single load percentage, but on future demand and the total energy consumption of the circuit.

CHILLER OPTIMIZATION · EXAMPLE CONTROL LOGIC

  • The outdoor temperature is falling.
  • Lower cooling demand is expected in 40 minutes.
  • In this example, the efficiency map shows a better EER for one chiller at 80% load.
  • The operation of both pumps is also included in the calculation.

Current load

Cooling demand 110%

Chiller 1

Running

55%
55%
Pump 1Running

Chiller 2

Running

55%
55%
Pump 2Running

2 chillers + 2 pumps. Current demand equals 110% of one chiller’s rated capacity.

In 40 min · forecast

Cooling demand 80%

Chiller 1

Running

40%
40%
Pump 1Running

Chiller 2

Running

40%
40%
Pump 2Running

2 chillers at 40% each + 2 pumps. A comparison scenario at lower cooling demand.

In 40 min · forecast

Cooling demand 80%

Chiller 1

Running

80%
80%
Pump 1Running

Chiller 2

Standby

0%
0%
Pump 2Standby

1 chiller at 80% + 1 pump. One unit meets the same forecast demand, provided the operating constraints allow it.

  • Switch off the second chiller once the load reduction is confirmed.
  • Set the first chiller to 80% and adjust the pump group accordingly.
  • Match the flow temperature to zone requirements.
  • Maintain indoor conditions and verify the actual result.

The change affects the operating mode of the whole system, not just one unit.

55% + 55% and 80% represent different times and different levels of demand. Energy use is compared at the same load: here, 40% + 40% versus 80% + standby. This is not a savings calculation; equipment performance maps, metering and checks on operating constraints are required.

The same logic. Different engineering circuits.

Examples of permissible strategies. The specific scope of control depends on the site’s connections and configuration.

HEAT PUMP OPTIMIZATION

Prepare the system for an overnight drop in temperature

Weather forecast + buffer tank state + thermal inertia.

  • Raise the buffer tank temperature in advance within permissible limits.
  • Use the building’s thermal inertia and adjust the heating curve.
  • Reduce peak demand for backup electric heating.
  1. Cold weather forecast
  2. Heat storage
  3. Night-time load

Storing heat in advance makes sense if the benefit outweighs the additional heat losses and heating costs.

AIR HANDLING UNIT

Adjust the air supply to actual occupancy

Zone occupancy + CO₂ + minimum air flow rates.

  • Adjust the fan output.
  • Match supply air heating or cooling to the reduced air flow rate.
  • Monitor CO₂ and maintain the minimum required ventilation rate.
  1. Fewer people
  2. Lower air flow
  3. CO₂ control

Reducing air flow must not compromise hygiene requirements, air balance or process extract ventilation.

WHOLE BUILDING

Match HVAC operation to available electrical capacity

HVAC + solar generation + battery + power limit.

  • Forecast simultaneous demand.
  • Shift some heating and cooling operation to periods when energy is available.
  • Coordinate thermal storage and the battery through the available controls.
  1. Load forecast
  2. Energy coordination
  3. Peak limiting

Battery coordination is only possible with the appropriate integration, permissions and agreed limits.

05. AI adjusts actual HVAC parameters

Through agreed BMS / PLC points. The available commands depend on protocols, access rights and existing controls.

Temperatures

Temperatures

  • Water flow temperature
  • Supply air temperature
  • Room setpoints

Equipment Load

Equipment loading

  • Compressor loading
  • Chiller stages
  • Heat pump stages

Flow

Flow rates

  • Pump speed
  • Fan speed
  • VAV air flow rate

Schedule

Schedule

  • Start and stop
  • Preheating
  • Precooling

Energy

Energy

  • Peak limiting
  • Thermal storage
  • Battery coordination

Operating Strategy

Operating strategy

  • Heating / cooling source selection
  • Cascade switching
  • Equipment priority

AI does more than display a recommendation to an engineer. It can automatically adjust permitted setpoints and operating modes.

06. Every decision is checked against the system’s response

After an operating mode change, the system observes how the building actually responds. If the response differs from the prediction, the model is refined.

The system gradually develops a better understanding of the specific site.

What the building owner gains

Energy consumption

Less unnecessary equipment operation.

Peak power demand

Fewer simultaneous peak loads.

Efficiency

Operation closer to efficient operating points.

Stability

Fewer abrupt changeovers and conflicts between systems.

Fewer manual adjustments. A transparent decision history. Accumulated data for further optimisation.

We do not optimise a single unit. We optimise the whole system.

Chiller + pumpA better operating point for the chiller may increase the pump group’s energy consumption.

Setpoint + comfortChanging the flow temperature affects indoor conditions and the load on other circuits.

Shutdown + backupStopping a unit may transfer its load to other equipment.

Overall outcome: energy + comfort + load + equipment service life.

Energy optimisation is assessed using measurements and comparable conditions, not just a change in setpoint.

REAL SYSTEM

How it works in practice

Yaroslav Smolko demonstrates HVAC Intelligence on a real engineering circuit: data, decision logic and changes to system operating modes.

How the system is connected

  1. 01

    Data

    We collect data from the BMS and equipment.

  2. 02

    Model

    We create a model of the control loop.

  3. 03

    Control

    We connect the optimisation module to the BMS / PLC.

  4. 04

    Optimization

    We activate the agreed control strategy and refine the model based on actual operation.

AI controls. Existing controls protect.

  • The equipment’s factory protection functions remain in place.
  • AI operates only within defined engineering limits.
  • If the AI layer becomes unavailable, the controls revert to a pre-agreed standard operating mode.

The fallback procedure is tested during integration setup.

Could your HVAC system be more efficient?

Show us your system, equipment and controls. We will determine how to build an intelligent control loop for it.

HVAC Intelligence turns building data into decisions, and decisions into real changes in equipment operation.